Introduction

La cyclophotocoagulation trans-sclérale par laser diode micropulsé (CPCTS-MP) réalise un cyclo-affaiblissement moins agressif que la CPCTS conventionnelle. L’objectif de cette étude était d’évaluer l’efficacité et la tolérance de la CPCTS-MP en vie réelle.

Matériels et méthodes

Étude rétrospective portant sur les CPCTS-MP réalisées dans notre service entre janvier 2017 et septembre 2019. Nous avons recueilli la pression intraoculaire (PIO) préopératoire, à 3 mois, 6 mois et en fin de suivi, les traitements hypotonisants administrés, ainsi que les complications. Le succès était défini par une PIO comprise entre 6 et 21mmHg avec diminution d’au moins un traitement, ou une diminution de plus de 20 % de la PIO.

Résultats

Trente yeux de 28 patients ont été inclus. La PIO préopératoire était de 27,2±10,6mmHg, avec 3,5±0,6 traitements hypotonisants, la déviation moyenne au champ visuel Humphrey 24–2 était de −21,9±6,9dB, et 43 % des yeux avaient préalablement bénéficié d’au moins une chirurgie filtrante. Le suivi moyen était de 13,5±8,1 mois. Onze patients (37 %) ont du être re-traités par CPCTS-MP pendant le suivi. À 3, 6 mois et en fin de suivi la PIO était respectivement de 18,3±7,3mmHg (−33 % ; p<0,0001), 22,5±11,8mmHg, (−17 % ; p=0,052), 22,7±12,0mmHg (−16,5 % ; p<0,050). Les taux de succès étaient restrospectivement de 57 %, 50 % et 53 % à 3, 6 mois et en fin de suivi. Les complications sévères se résumaient à trois ulcères cornéens et deux hypotonies oculaires transitoires sans séquelle visuelle.

Conclusion

La CPCTS-MP est une procédure efficace sur des glaucomes sévères et/ou réfractaires, mais des retraitements sont nécessaires dans plus d’un tiers des cas. Des études supplémentaires sont requises pour définir les facteurs prédictifs de succès et les indications de re-traitement.

Le texte complet de cet article est disponible en PDF.

Summary

Micropulse Transscleral Cyclophotocoagulation (MP-TSCP) is a recently developed cyclodestructive procedure less aggressive than conventional TSCP. In this study, we aimed to evaluate the safety and efficacy of MP-TSCP in a real-life setting.

Material and methods

We retrospectively included all MP-TSCP cases performed in the Bicêtre Hospital Ophthalmology department between January 2017 and September 2019. Intraocular pressure (IOP) and hypotensive medications were recorded preoperatively, at month 1, 3, 6 and at the conclusion of follow-up, as well as postoperative adverse events. Success was defined as an IOP between 6 and 21mmHg with a decrease of at least one medication or an IOP reduction>20%.

Results

Thirty eyes (28 patients) were included. Preoperative IOP was 27.2±10.6mmHg, with 3.5±0.6 hypotensive medications, the mean deviation on the Humphrey 24-2 visual field was −21.9±6.9dB, and 43% of eyes had a past history of filtering surgery. The mean follow-up was 13.5±8.1 months. Eleven patients (37%) had to be retreated with MP-TSCP during follow-up. At 3 and 6 months and at the conclusion of follow-up, the IOP was 18.3±7.3mmHg (−33%; P<0.0001), 22.5±11.8mmHg, (−17%; P=0.052), 22.7±12.0mmHg (−16,5%; P<0.050), respectively. The success rates were 57%, 50% et 53% at 3 months, 6 months and at the conclusion of follow-up, respectively. Severe adverse events included 3 cases of corneal ulcers and 2 cases of severe but transient ocular hypotony without visual impairment.

Conclusion

MP-TSCP is an effective procedure for severe and/or refractory glaucoma, but retreatments are required in more than one-third of cases. Further studies are warranted to define factors predictive of success and indications for retreatment.

Le texte complet de cet article est disponible en PDF.

Mots clés : Glaucome réfractaire, Cyclo-affaiblissement, Laser diode micropulsé

Keywords : Refractory glaucoma, Cyclophotocaogulation, Micropulsed diode laser


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 44 - N° 3

P. 350-357 - mars 2021 Retour au numéro
Article précédent Article précédent
  • The effect of halofug?none and pirfenidone on wound healing in experimental glaucoma filtration surgery
  • K. Kasar, T. Demir, M.M. Akin, S. Gungor Kobat
| Article suivant Article suivant
  • Dépistage des troubles visuels à l’âge scolaire : les données du projet pilote PlanVue®
  • D. Georgelin, F. Jonqua, K. Makowiecka, S. Wheeler, C. Baudouin, D. Brémond-Gignac, A. Labbé

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.